HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
  1. Problems
  2. /A radiographer changes a tube from 60 kV and 10 mA to 90 kV and 5.0 mA, to image a thicker part of…
HardPhysicsHigh School (11–12)Medical PhysicsNumericalConceptualA-Level

A radiographer changes a tube from 60 kV and 10 mA to 90 kV and 5.0 mA, to image a thicker part of…

StemPy LabContributed by StemPy Lab

Try it on paper first. A hint, the key idea and the worked solution are here when you need them.

A radiographer changes a tube from 606060 kV and 101010 mA to 909090 kV and 5.05.05.0 mA, to image a thicker part of the body. Find the shortest wavelength before and after, and the number of electrons each second before and after. Find the power of the electron beam before and after. Suppose the output of X-rays is roughly proportional to IV2IV^2IV2. By what factor does the output change? Which beam passes more easily through the body, and why?

Check your answer

Work it out on paper, then type your number. The answer itself stays hidden.

pm
pm
W
Need a reminder? The key ideaShowHide

An electron that crosses a voltage VVV arrives with the energy eVeVeV. The most energetic photon takes all of it, so

λmin=hceV\displaystyle \lambda_{min} = \frac{hc}{eV}λmin​=eVhc​

with hc/e=1239.8hc/e = 1239.8hc/e=1239.8 nm V. The power of the beam of electrons is P=IVP = IVP=IV, and only about 1 %1\ \%1 % of it becomes X-rays.

The worked solution

Check an answer or open a hint to unlock the worked solution.

Have you tried it?

Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.

Step 1. Wavelengths. Before: 1239.8 nm V60 000 V=20.7\dfrac{1239.8\ \text{nm V}}{60\,000\ \text{V}} = 20.760000 V1239.8 nm V​=20.7 pm. After: 1239.8 nm V90 000 V=13.8\dfrac{1239.8\ \text{nm V}}{90\,000\ \text{V}} = 13.890000 V1239.8 nm V​=13.8 pm.

Step 2. Electrons. Before: 0.010 A1.602×10−19 C=6.24×1016\dfrac{0.010\ \text{A}}{1.602 \times 10^{-19}\ \text{C}} = 6.24 \times 10^{16}1.602×10−19 C0.010 A​=6.24×1016 each second. After, half the current: 3.12×10163.12 \times 10^{16}3.12×1016 each second.

Step 3. Power. Before: 0.010 A×60 000 V=6000.010\ \text{A} \times 60\,000\ \text{V} = 6000.010 A×60000 V=600 W. After: 0.0050 A×90 000 V=4500.0050\ \text{A} \times 90\,000\ \text{V} = 4500.0050 A×90000 V=450 W.

Step 4. Output. 5.010×1.52=1.125\dfrac{5.0}{10} \times 1.5^2 = 1.125105.0​×1.52=1.125.

Answer: 20.720.720.7 pm and 13.813.813.8 pm; 6.24×10166.24 \times 10^{16}6.24×1016 and 3.12×10163.12 \times 10^{16}3.12×1016 electrons each second; 600600600 W and 450450450 W; the output grows by a factor of 1.1251.1251.125.

Why. The second beam is harder. Its photons reach higher energies, where attenuation in tissue is smaller, so more of them pass through a thick part. The output stays about the same, while the anode gets less heat.

Log in to save this for later
← All Problems
← A tube for X-rays of the chest runs at 120 kV with a tube current of 4.0 mA…A tube gives a short exposure of 30 kW for 0.10 s… →
More onMedical Physics

Discussion (0)

Log in to join the discussion.

Loading…

Learn it in

  1. Making X-rays: the tube and its spectrumX-Ray Imaging, CT and MRI

More on this topic

  1. A tumour of mass 0.12 kg is to receive 60 Gy in 30 equal fractions…Advanced
  2. After a large dose of iodine-131, a patient gives a dose rate of 25 microsievert per hour at 1.0 m…Hard
  3. At the start of a scan, a patient holds 300 MBq of fluorine-18, whose half-life is 109.8 min…Advanced
A cyclotron makes fluorine-18, with a half-life of 109.8 min, for a hospital 2.0 h away…Hard
  • A PET ring has a diameter of 80 cm. For one event, the photon that reaches detector A arrives 300…Hard
  • All problems on this topic →