HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
  1. Problems
  2. /A beam holds soft photons of 20 keV and harder ones of 60 keV…
HardPhysicsHigh School (11–12)Medical PhysicsNumericalpythonA-Level

A beam holds soft photons of 20 keV and harder ones of 60 keV…

StemPy LabContributed by StemPy Lab

Try it on paper first. A hint, the key idea and the worked solution are here when you need them.

A beam holds soft photons of 202020 keV and harder ones of 606060 keV. For aluminium, μ=0.70 mm−1\mu = 0.70\ \text{mm}^{-1}μ=0.70 mm−1 at 202020 keV and μ=0.050 mm−1\mu = 0.050\ \text{mm}^{-1}μ=0.050 mm−1 at 606060 keV. Find the share of each kind that passes 2.02.02.0 mm of aluminium. Find the half-value thickness for the soft photons. What thickness lets only 5.0 %5.0\ \%5.0 % of the soft photons through, and what share of the hard ones passes that thickness?

Check your answer

Work it out on paper, then type your number. The answer itself stays hidden.

%
%
mm
mm
%
Need a reminder? The key ideaShowHide

A beam falls off as I=I0e−μxI = I_0e^{-\mu x}I=I0​e−μx, and the exponents of layers in a row add. The half-value thickness is

x1/2=ln⁡2μ\displaystyle x_{1/2} = \frac{\ln 2}{\mu}x1/2​=μln2​

The mass attenuation coefficient is μm=μ/ρ\mu_m = \mu/\rhoμm​=μ/ρ. Photoelectric absorption grows about as Z3Z^3Z3.

The worked solution

Check an answer or open a hint to unlock the worked solution.

Have you tried it?

Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.

Step 1. Through 2.0 mm. Soft: e−0.70×2.0=e−1.40=0.247e^{-0.70 \times 2.0} = e^{-1.40} = 0.247e−0.70×2.0=e−1.40=0.247, so 24.7 %24.7\ \%24.7 %. Hard: e−0.050×2.0=e−0.10=0.905e^{-0.050 \times 2.0} = e^{-0.10} = 0.905e−0.050×2.0=e−0.10=0.905, so 90.5 %90.5\ \%90.5 %.

Step 2. Half-value thickness. x1/2=0.6930.70 mm−1=0.99x_{1/2} = \dfrac{0.693}{0.70\ \text{mm}^{-1}} = 0.99x1/2​=0.70 mm−10.693​=0.99 mm.

Step 3. Down to 5.0 %. x=ln⁡200.70 mm−1=3.000.70 mm−1=4.28x = \dfrac{\ln 20}{0.70\ \text{mm}^{-1}} = \dfrac{3.00}{0.70\ \text{mm}^{-1}} = 4.28x=0.70 mm−1ln20​=0.70 mm−13.00​=4.28 mm.

Step 4. The hard photons there. e−0.050×4.28=e−0.214=0.807e^{-0.050 \times 4.28} = e^{-0.214} = 0.807e−0.050×4.28=e−0.214=0.807, so 80.7 %80.7\ \%80.7 %.

Answer: 24.7 %24.7\ \%24.7 % and 90.5 %90.5\ \%90.5 %; 0.990.990.99 mm; 4.284.284.28 mm, which passes 80.7 %80.7\ \%80.7 % of the hard photons.

Check. The filter removes most of the soft photons and keeps most of the hard ones. The soft photons would only have been absorbed in the skin, adding dose and no picture.

Log in to save this for later
← All Problems
← A tube gives a short exposure of 30 kW for 0.10 s…A beam crosses a finger 2.0 cm thick. One line passes through soft tissue only… →
More onMedical Physics

Discussion (0)

Log in to join the discussion.

Loading…

Learn it in

  1. Attenuation, contrast and the X-ray imageX-Ray Imaging, CT and MRI

More on this topic

  1. A tumour of mass 0.12 kg is to receive 60 Gy in 30 equal fractions…Advanced
  2. After a large dose of iodine-131, a patient gives a dose rate of 25 microsievert per hour at 1.0 m…Hard
  3. At the start of a scan, a patient holds 300 MBq of fluorine-18, whose half-life is 109.8 min…Advanced
A cyclotron makes fluorine-18, with a half-life of 109.8 min, for a hospital 2.0 h away…Hard
  • A PET ring has a diameter of 80 cm. For one event, the photon that reaches detector A arrives 300…Hard
  • All problems on this topic →