HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
  1. Problems
  2. /A beam crosses a finger 2.0 cm thick. One line passes through soft tissue only…
HardPhysicsHigh School (11–12)Medical PhysicsNumericalConceptualA-Level

A beam crosses a finger 2.0 cm thick. One line passes through soft tissue only…

StemPy LabContributed by StemPy Lab

Try it on paper first. A hint, the key idea and the worked solution are here when you need them.

A beam crosses a finger 2.02.02.0 cm thick. One line passes through soft tissue only. Another line passes through 1.21.21.2 cm of bone and 0.80.80.8 cm of soft tissue. At a low tube voltage, μ=0.25 cm−1\mu = 0.25\ \text{cm}^{-1}μ=0.25 cm−1 for tissue and 0.80 cm−10.80\ \text{cm}^{-1}0.80 cm−1 for bone. At a high voltage they fall to 0.18 cm−10.18\ \text{cm}^{-1}0.18 cm−1 and 0.40 cm−10.40\ \text{cm}^{-1}0.40 cm−1. For each voltage, find the share of the beam along each line, and the ratio of the two. Which voltage gives the better contrast, and what is the cost of choosing it?

Check your answer

Work it out on paper, then type your number. The answer itself stays hidden.

%
Need a reminder? The key ideaShowHide

A beam falls off as I=I0e−μxI = I_0e^{-\mu x}I=I0​e−μx, and the exponents of layers in a row add. The half-value thickness is

x1/2=ln⁡2μ\displaystyle x_{1/2} = \frac{\ln 2}{\mu}x1/2​=μln2​

The mass attenuation coefficient is μm=μ/ρ\mu_m = \mu/\rhoμm​=μ/ρ. Photoelectric absorption grows about as Z3Z^3Z3.

The worked solution

Check an answer or open a hint to unlock the worked solution.

Have you tried it?

Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.

Step 1. Low voltage. Tissue only: e−0.25×2.0=e−0.50=0.607e^{-0.25 \times 2.0} = e^{-0.50} = 0.607e−0.25×2.0=e−0.50=0.607. With bone: e−0.25×0.8−0.80×1.2=e−1.16=0.313e^{-0.25 \times 0.8 - 0.80 \times 1.2} = e^{-1.16} = 0.313e−0.25×0.8−0.80×1.2=e−1.16=0.313. The ratio is 0.6070.313=1.93\dfrac{0.607}{0.313} = 1.930.3130.607​=1.93.

Step 2. High voltage. Tissue only: e−0.18×2.0=e−0.36=0.698e^{-0.18 \times 2.0} = e^{-0.36} = 0.698e−0.18×2.0=e−0.36=0.698. With bone: e−0.18×0.8−0.40×1.2=e−0.624=0.536e^{-0.18 \times 0.8 - 0.40 \times 1.2} = e^{-0.624} = 0.536e−0.18×0.8−0.40×1.2=e−0.624=0.536, so 53.6 %53.6\ \%53.6 %. The ratio is 0.6980.536=1.30\dfrac{0.698}{0.536} = 1.300.5360.698​=1.30.

Step 3. A shortcut. The ratio is e(μb−μt)×1.2 cme^{(\mu_b - \mu_t) \times 1.2\ \text{cm}}e(μb​−μt​)×1.2 cm: e0.66=1.93e^{0.66} = 1.93e0.66=1.93 and e0.264=1.30e^{0.264} = 1.30e0.264=1.30.

Answer: ratios of 1.931.931.93 at the low voltage and 1.301.301.30 at the high voltage. The low voltage gives better contrast.

The cost. At the low voltage more of the beam is absorbed in the finger, so the dose is larger. For a thin part such as a finger that is acceptable, and a low voltage is the usual choice.

Log in to save this for later
← All Problems
← A beam holds soft photons of 20 keV and harder ones of 60 keV…At the energies of a diagnostic beam, absorption by the photoelectric effect, for each atom of the… →
More onMedical Physics

Discussion (0)

Log in to join the discussion.

Loading…

Learn it in

  1. Attenuation, contrast and the X-ray imageX-Ray Imaging, CT and MRI

More on this topic

  1. A tumour of mass 0.12 kg is to receive 60 Gy in 30 equal fractions…Advanced
  2. After a large dose of iodine-131, a patient gives a dose rate of 25 microsievert per hour at 1.0 m…Hard
  3. At the start of a scan, a patient holds 300 MBq of fluorine-18, whose half-life is 109.8 min…Advanced
A cyclotron makes fluorine-18, with a half-life of 109.8 min, for a hospital 2.0 h away…Hard
  • A PET ring has a diameter of 80 cm. For one event, the photon that reaches detector A arrives 300…Hard
  • All problems on this topic →