A stop-watch, a thermometer, a balance and a measuring cylinder look simple. This lesson names the apparatus for time, temperature, mass and volume, shows how to choose between them, and teaches how to read them to the right precision.
about 25 min1 simulation1 practice question
Lesson 1 of 3Show all lessonsHide
Try the code and the simulations beside the lesson.
Four quantities, seven pieces of apparatus
Nearly every experiment in the laboratory measures time, temperature, mass or volume. Each has its own apparatus.
Time: a stop-watch. A school stop-watch is read to about 1s.
Temperature: a thermometer. A laboratory thermometer has a scale from −10∘C to 110∘C, with a mark for every 1∘C.
Mass: a balance. A school balance reads to 0.1g or better.
Volume of a liquid: a measuring cylinder, a burette or a volumetric pipette.
Volume of a gas: a gas syringe.
A row of seven labelled drawings of laboratory apparatus. A stop-watch measures time. A thermometer measures temperature. A balance with a digital display measures mass. A measuring cylinder, a volumetric pipette with one mark on its neck and a burette with a tap measure the volume of a liquid. A gas syringe, a barrel with a plunger, measures the volume of a gas. Under each drawing is the quantity it measures.
Which apparatus for which job?
The three pieces for a liquid differ in how exact they are and in what they can do.
A measuring cylinder is quick and fairly rough. School cylinders hold 10, 25, 50 or 100cm3. Use one when the volume does not have to be exact, for example the water in which a salt dissolves.
A volumetric pipette delivers one fixed volume very exactly, for example 25.0cm3. You fill it with a pipette filler. Never use your mouth.
A burette is a long tube with a tap and a scale. It can deliver any volume up to 50cm3, drop by drop. You read the scale before and after. The volume delivered is the difference.
A gas syringe is a barrel with a plunger and a scale. The gas pushes the plunger out, and you read the volume of gas directly.
A good rule is to use the cheapest, quickest apparatus that is exact enough for the job. You need a pipette for the 25.0cm3 of alkali in a titration. A cylinder would do for the water you wash the flask with.
Reading a scale
Read the scale with your eye level with the liquid surface. A liquid surface curves, and you read the bottom of the curve. Read to the nearest half division where the question asks for it. Write the unit with every reading.
Half a division is the size of the largest error. The same error matters less in a large reading. As a percentage:
largest error=readingdivision÷2×100
Example. A cylinder has divisions of 1cm3. A reading of 25cm3 can be 0.5cm3 out. That is 250.5×100=2%. A burette has divisions of 0.1cm3, so a reading of 25.0cm3 can be 0.05cm3 out. That is 0.2%. The burette is ten times more exact.
The red line falls as the volume grows. A small volume measured with big divisions has a large percentage error. This is why you choose a small cylinder for a small volume.
Practise with new numbers
Try it in Python
The program compares the largest error of a cylinder and a burette for the same volume.
Common mistakes
Reading the top of the surface. Read the bottom of the curve, with your eye level with it.
Using a measuring cylinder when the volume must be exact. Use a volumetric pipette or a burette.
Forgetting the unit. A reading is a number and a unit, such as 24.50cm3.
Treating the burette reading as the volume delivered. The volume delivered is the final reading minus the start reading.
Using a gas syringe for a liquid, or a pipette for a gas. Each piece of apparatus suits one kind of job.
Remember these
Time: stop-watch. Temperature: thermometer. Mass: balance. Liquid volume: measuring cylinder, burette, volumetric pipette. Gas volume: gas syringe.
A volumetric pipette delivers one fixed volume exactly. A burette delivers any volume, read as a difference.
Read to the nearest half division. The largest error is half a division.
The same error is a smaller percentage of a larger reading.
Check yourself
Try each one on your own first. If you are stuck, open a hint. Then check with Show the answer.
Name the apparatus you would use to find (a) the time for a reaction, (b) the volume of hydrogen made, and (c) the mass of a piece of magnesium.
Why do we use a volumetric pipette, not a measuring cylinder, to put exactly 25.0cm3 of alkali in a flask?
A thermometer has a mark for every 1∘C. To what size of step can you read it if you read to the nearest half division?
A burette has divisions of 0.1cm3. The bottom of the liquid surface is halfway between the 12.3 and 12.4 marks. What do you write?
A burette starts at 0.40cm3 and ends at 17.90cm3. What volume was delivered?
References
Cambridge IGCSE Chemistry 0620 syllabus for 2026 to 2028, section 12.1 (Experimental design), Core 1.
Cambridge IGCSE Chemistry 0620 syllabus, Details of the assessment: the apparatus list and reading to the nearest half-scale division.
Enroll free in Experimental Design and Acid-Base Titrations
Every lesson is open to read. Enrolling also lets you:
Mark lessons done and carry on where you stopped.
Take the tests of this lesson and its course.
Count the course towards the certificate for its chapter.