HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
Colorimetry and Titration Technique: Concentration and Its Uncertainty
  1. 1Colorimetry: the Beer-Lambert law at the bench
  2. 2Colorimetry at work: rates, formulas of complexes and equilibrium
  3. 3Titration technique, uncertainty and error
  1. Chemistry
  2. /Colorimetry and Titration Technique: Concentration and Its Uncertainty
  3. /Titration technique, uncertainty and error

Course 40.2·Lesson 3 of 3

Titration technique, uncertainty and error

Two students titrate the same acid and get 22.40 cm³ and 22.45 cm³. Is that a real difference? Every reading has a limit to how well it can be made. This lesson shows how to read a burette, choose concordant titres, put a size on the uncertainty of a result, and tell a random error from a systematic one.

about 25 min1 simulation1 practice question
Lesson 3 of 3Show all lessonsHide
Colorimetry and Titration Technique: Concentration and Its Uncertainty
  1. 1Colorimetry: the Beer-Lambert law at the bench
  2. 2Colorimetry at work: rates, formulas of complexes and equilibrium
  3. 3

Try the code and the simulations beside the lesson.

Reading a burette

The top of the liquid in a burette, enlarged. The surface curves down in the middle, forming a meniscus. An eye drawn level with the bottom of the meniscus reads 22.40 cm³ on the scale. Two other eyes, one above and one below, are crossed out and labelled parallax error.
  1. Rinse the burette with water, then with a little of the solution it will hold. Water left inside would dilute it.
  2. Fill it above zero and run some out, so that the tip has no air bubble.
  3. Read the bottom of the meniscus, the curved surface of the liquid, with your eye level with it. Reading from above or below gives a parallax error.
  4. A burette is marked every 0.1 cm³. Read it to the nearest half division, 0.05 cm³, and record two decimal places: 22.40, not 22.4.

Titres

The first titration is a rough titration, done fast to find the end point roughly. Then repeat with care, adding the last few drops one at a time. Titres that agree within 0.10 cm³ are concordant. The mean of the concordant titres is the value we use. Leave out the rough titre and any titre that does not agree.

Take titres of 24.60 (rough), 24.15, 24.40, 24.20 and 24.10 cm³. The concordant ones are 24.15, 24.20 and 24.10 cm³, and their mean is 24.15 cm³.

The uncertainty of one measurement

Every instrument has an uncertainty, the range within which the true value is likely to lie. Typical values are:

ApparatusUncertainty
burette, one reading±0.05 cm3\pm 0.05\ \text{cm}^3±0.05 cm3
25.00 cm³ pipette±0.06 cm3\pm 0.06\ \text{cm}^3±0.06 cm3
250.0 cm³ flask±0.3 cm3\pm 0.3\ \text{cm}^3±0.3 cm3
balance to 0.001 g±0.0005 g\pm 0.0005\ \text{g}±0.0005 g a reading

A titre is the difference of two burette readings, so its uncertainty is ±0.10 cm3\pm 0.10\ \text{cm}^3±0.10 cm3. A mass found by weighing a boat, adding the solid and weighing again also uses two readings.

The percentage uncertainty compares the uncertainty with the value:

%u=uncertaintyvalue×100\displaystyle \%u = \dfrac{\text{uncertainty}}{\text{value}} \times 100%u=valueuncertainty​×100

A titre of 22.40 cm³ has %u=0.1022.40×100=0.45 %\%u = \dfrac{0.10}{22.40} \times 100 = 0.45\ \%%u=22.400.10​×100=0.45 %. A titre of 8.50 cm³ has 1.18 %. Small titres have large percentage uncertainties. That is why a titration is planned to give a titre between about 20 and 30 cm³.

Combining uncertainties

  • When values are added or subtracted, add their absolute uncertainties.
  • When values are multiplied or divided, add their percentage uncertainties.

A concentration found as c1=c2V2/V1c_1 = c_2 V_2 / V_1c1​=c2​V2​/V1​ is a product and a quotient, so we add the percentage uncertainties of c2c_2c2​, V2V_2V2​ and V1V_1V1​. A-Level and IB add them this way. Research laboratories often combine them as the square root of the sum of the squares, which gives a smaller total. Use the method your syllabus asks for.

Slide the titre down to 10 cm³. The burette now gives twice the uncertainty of a 20 cm³ titre.

Accuracy, precision and two kinds of error

  • A result is accurate when it is close to the true value.
  • A set of results is precise when the results are close to each other.

A random error scatters results on both sides of the mean, such as a small misjudgement of the end point. Repeats and a mean reduce it. A systematic error pushes every result the same way, such as a burette not rinsed with the titrant, or an indicator that changes colour too late. Repeats do not remove it.

How do we spot a systematic error? Find the percentage error:

% error=∣Δ∣accepted×100\displaystyle \%\ \text{error} = \dfrac{|\Delta|}{\text{accepted}} \times 100% error=accepted∣Δ∣​×100

Here Δ\DeltaΔ is the measured value minus the accepted value.

If the percentage error is larger than the total percentage uncertainty, the uncertainties of the apparatus cannot explain it. Something systematic is wrong.

Significant figures

Give a result to the number of significant figures of the least precise data. A titre of 22.40 cm³ and a concentration of 0.100 mol/dm³ give an answer to 3 significant figures.

Practise with new numbers

Try it in Python

The program picks the concordant titres, finds their mean, and adds the percentage uncertainties.

Read it first. Predict which titres it keeps. Then run it.

1. Change the third titre to 24.25. Is it now concordant?

2. Change the pipette uncertainty to 0.03 cm³, the value for a class A pipette. What is the new total?

Common mistakes

  • Writing 22.4 for a burette reading. Write two decimal places: 22.40.
  • Using one reading for a titre. A titre has two readings, so ±0.10 cm3\pm 0.10\ \text{cm}^3±0.10 cm3.
  • Averaging every titre. Use the concordant ones only.
  • Adding absolute uncertainties in a product. Add the percentages instead.

Remember these

  • Burette: read the bottom of the meniscus at eye level, to 0.05 cm³.
  • Concordant titres agree within 0.10 cm³.
  • %u=uncertainty/value×100\%u = \text{uncertainty}/\text{value} \times 100%u=uncertainty/value×100. Products and quotients: add percentages.
  • Percentage error larger than the percentage uncertainty means a systematic error.

References

  • OpenStax Chemistry 2e, Chapter 1, section 1.5 on measurement uncertainty, accuracy and precision.
  • NCERT Chemistry Part I for Class 11, Unit 1, Some Basic Concepts of Chemistry, on significant figures.

Check yourself

Try each one on your own first. If you are stuck, open a hint. Then check with Show the answer.

  1. Titres of 17.35, 17.60, 17.40 and 17.30 cm³ are recorded after a rough one. Which are concordant, and what is the mean?
  1. What is the percentage uncertainty of a 10.00 cm³ titre?
  1. A student forgets to rinse the burette with the alkali, and water is left inside. Is the error random or systematic, and is the titre too large or too small?
  1. Three results are 0.1052, 0.1053 and 0.1051 mol/dm³, and the true value is 0.1000 mol/dm³. Are they accurate, precise, or both?

Enroll free in Colorimetry and Titration Technique: Concentration and Its Uncertainty

Every lesson is open to read. Enrolling also lets you:

  • Mark lessons done and carry on where you stopped.
  • Take the tests of this lesson and its course.
  • Count the course towards the certificate for its chapter.
No payment. You can leave at any time.

Problems (4)

A 25.00 cm³ pipette of hydrochloric acid, uncertain to ± 0.06 cm³, is titrated with sodium…Hard · High School (11–12) · by StemPy Lab
A student titrates 25.00 cm³ portions of a sodium carbonate solution with 0.1050 mol/dm³…Advanced · High School (11–12) · by StemPy Lab
A class standardises a sodium hydroxide solution whose accepted concentration is 0.1100 mol/dm³…Hard · High School (11–12) · by StemPy Lab
That was the last lessonBack to the course: take the test
← Colorimetry and Titration Technique: Concentration and Its Uncertainty
← Colorimetry at work: rates, formulas of complexes and equilibriumNext →

Discussion (0)

Log in to join the discussion.

Loading…

1 Python program
4 questions to check yourself

This lesson is free to read. Enroll free to keep your place and take the tests.

Titration technique, uncertainty and error
A student must find the purity of sodium hydrogencarbonate, NaHCO₃ (84 g/mol)…Advanced · High School (11–12) · by StemPy Lab

Python Labs (1)

Concordant titres and their uncertaintyPython Lab · by StemPy Lab

Question Sets (1)

Colorimetry and Uncertainty: Think It Through10 questions · by StemPy Lab

Notes (1)

Colorimetry and Titration Technique: Quick RevisionNote · by StemPy Lab