Colorimetry at work: rates, formulas of complexes and equilibrium
A colorimeter does more than read one concentration. It can watch a colour fade, show how many ligands sit on a metal ion, and measure how far a reaction goes. This lesson uses absorbance to find a rate constant, the formula of a complex by the method of continuous variation, and an equilibrium constant.
about 25 min1 simulation1 practice question
Lesson 2 of 3Show all lessonsHide
Try the code and the simulations beside the lesson.
Following a reaction
Suppose only one substance in a reaction is coloured. Then its absorbance is proportional to its concentration at every moment. We do not need to stop the reaction or take samples. We leave the cuvette in the colorimeter and read A every few seconds.
Purple crystal violet, a dye, fades in alkali. With a large excess of hydroxide ions, the reaction behaves as first order in the dye. We call this pseudo-first-order. Then
lnAA0=kt
So a graph of lnA against t is a straight line with slope −k. The half-life is t1/2=ln2/k.
Take a dye whose absorbance falls from 0.720 to 0.360 in 80 s. The absorbance halved, so t1/2=80s and k=0.693/80s=8.66×10−3s−1.
When the product is coloured. If the product absorbs as well, the absorbance does not go to zero. It goes to a final value A∞. Then we use lnA∞−AA∞−A0=kt for a product that grows, or the same form with the signs turned for one that fades.
Practise with new numbers
How many ligands? The method of continuous variation
Iron(II) ions and a ligand L form an orange red complex. Is it FeL, FeL2 or FeL3? The method of continuous variation, also called Job's method, answers this.
Make solutions of the metal ion and of the ligand with the same concentration.
Mix them in different shares, always to the same total volume: 1 cm³ and 9 cm³, then 2 cm³ and 8 cm³, and so on.
Measure the absorbance of each mixture at the wavelength the complex absorbs.
The total amount of metal plus ligand is the same in every mixture. The most complex forms when the two are mixed in the ratio of the formula. For MLn the peak is at a mole fraction of ligand
xmax=n+1n
So a peak at 0.50 means ML, a peak at 0.667 means ML2, and a peak at 0.75 means ML3.
A graph of the method of continuous variation. Absorbance is plotted against the mole fraction of the ligand from 0 to 1. Two straight lines rise from zero at the left and fall to zero at the right and meet at a peak at a mole fraction of 0.75, labelled ML3. The measured points curve a little below the peak.
The real points curve below the sharp peak, because the complex is never formed completely. We draw two straight lines through the points on each side and use where they meet. Iron(II) with 1,10-phenanthroline peaks at 0.75: the complex is [Fe(phen)3]2+.
An equilibrium constant from colour
Iron(III) ions and thiocyanate ions give a blood red complex:
Fe3++SCN−⇌[FeSCN]2+
Only the complex is coloured. Its absorbance gives its concentration at equilibrium, through A=εcl. The rest follows from a table of amounts.
Suppose we start with 2.00×10−3 mol/dm³ of iron(III) and 1.00×10−3 mol/dm³ of thiocyanate, and the complex is found to be 2.50×10−4 mol/dm³. At equilibrium iron(III) is 1.75×10−3 and thiocyanate 7.5×10−4 mol/dm³. So
Kc=[Fe3+][SCN−][FeSCN2+]
Putting in the values, Kc=1.75×10−3×7.5×10−42.50×10−4, which is 190.
The unit of Kc here is dm³/mol. Values near 100 to 200 are found at room temperature. They depend on the temperature and on the other ions present.
Two coloured substances at once
If two substances absorb, the absorbances add: A=εXcXl+εYcYl. Measure at two wavelengths and you have two equations for the two concentrations. This is how a chemist finds cobalt and nickel in one solution.
Try it in Python
The program fits lnA against time for a fading dye and finds the rate constant and the half-life.
Common mistakes
Plotting A against t for a first-order reaction. Plot lnA.
Changing the total volume in Job's method. It must stay the same.
Reading the peak of the curve, not of the lines. Extend the straight parts and use where they meet.
Forgetting what was used up. In the equilibrium table, take the complex away from both starting amounts.
Remember these
First order: ln(A0/A)=kt, and t1/2=ln2/k.
Job's method: peak at x=n/(n+1).
Absorbances of two substances add.
References
OpenStax Chemistry 2e, Chapter 12, section 12.4 on integrated rate laws, and Chapter 13 on equilibrium constants.
IChO Regulations, Appendix C, the topic on light and colour, which lists the Lambert-Beer law.
Check yourself
Try each one on your own first. If you are stuck, open a hint. Then check with Show the answer.
In a Job's method experiment the peak is at a ligand mole fraction of 0.667. What is the formula of the complex?
A dye fades in a first-order reaction and its absorbance falls to a quarter in 6.0 min. What is its half-life?
Why must the total volume be the same in every mixture of Job's method?
In the iron thiocyanate equilibrium, why is the absorbance read at a blue green wavelength?
Enroll free in Colorimetry and Titration Technique: Concentration and Its Uncertainty
Every lesson is open to read. Enrolling also lets you:
Mark lessons done and carry on where you stopped.
Take the tests of this lesson and its course.
Count the course towards the certificate for its chapter.