Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
Two samplers stand side by side on a roof for 24 hours. A high volume sampler, with no cyclone, runs at , and its filter gains . A respirable dust sampler, whose cyclone removes the particles larger than , runs at , and its filter gains . (a) What is the concentration of all the suspended particles? (b) What is the ? (c) How much of the dust, per cubic metre, is coarser than ? (d) The 24-hour standard for is . Is it met?
Check an answer or open a hint to unlock the worked solution.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Step 1. Volumes. and .
Step 2. All particles. .
Step 3. PM10. .
Step 4. The coarse part. .
Step 5. The standard. is above , so the 24-hour standard is not met.
Answer: , and ; not met.
Log in to join the discussion.
Loading…
A high volume sampler or a respirable dust sampler gives
with the mass in micrograms, the flow in cubic metres a minute and the time in minutes.