HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
  1. Problems
  2. /Solutions of a metal ion M and a ligand L, each at 1.00 × 10⁻⁴ mol/dm³, are mixed in nine shares to…
AdvancedChemistryHigh School (11–12)Principles Related to Practical ChemistryNumericalOlympiadAEEE (Amrita)AMUEEEAP EAPCETBCECECOMEDK UGET
+16 more exams
GUJCETIAT (IISER)JCECEJKCETKCETKEAMKIITEELPUNESTMET (Manipal)MHT-CETNEST (NISER)OJEESRMJEEETS EAPCET
Olympiad

Solutions of a metal ion M and a ligand L, each at 1.00 × 10⁻⁴ mol/dm³, are mixed in nine shares to…

StemPy LabContributed by StemPy Lab

Try it on paper first. A hint, the key idea and the worked solution are here when you need them.

Solutions of a metal ion M and a ligand L, each at 1.00×10−41.00 \times 10^{-4}1.00×10−4 mol/dm³, are mixed in nine shares to a total of 10.0 cm³. The mole fraction of L runs from 0.1 to 0.9. The absorbances at the wavelength of the complex, in a 1.00 cm cell, are 0.037, 0.074, 0.111, 0.148, 0.185, 0.222, 0.259, 0.222 and 0.111. Neither M nor L absorbs at this wavelength. Draw the two straight lines through the points and find the mole fraction where they meet, the number of ligands on each metal ion, and the molar absorption coefficient of the complex.

Check your answer

Work it out on paper, then type your number. The answer itself stays hidden.

L/(mol cm)
Need a reminder? The key ideaShowHide

The worked solution

Check an answer or open a hint to unlock the worked solution.

Have you tried it?

Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.

Step 1. The two lines. The first seven points rise by 0.037 for each 0.1, so A=0.37xA = 0.37xA=0.37x. The last two points fall on A=1.11(1−x)A = 1.11(1 - x)A=1.11(1−x).

Step 2. Where they meet. 0.37x=1.11(1−x)0.37x = 1.11(1 - x)0.37x=1.11(1−x), so 1.48x=1.111.48x = 1.111.48x=1.11 and x=0.75x = 0.75x=0.75.

Step 3. The formula. nn+1=0.75\dfrac{n}{n + 1} = 0.75n+1n​=0.75 gives n=3n = 3n=3. The complex is ML3\text{ML}_{3}ML3​.

Step 4. The coefficient. At x=0.75x = 0.75x=0.75 the metal is 0.25×1.00×10−4=2.5×10−5 mol/dm30.25 \times 1.00 \times 10^{-4} = 2.5 \times 10^{-5}\ \text{mol/dm}^30.25×1.00×10−4=2.5×10−5 mol/dm3, all bound as ML3\text{ML}_{3}ML3​. The lines meet at A=0.2775A = 0.2775A=0.2775. So ε=0.27752.5×10−5 mol/dm3×1.00 cm=11100 L/(mol cm)\varepsilon = \dfrac{0.2775}{2.5 \times 10^{-5}\ \text{mol/dm}^3 \times 1.00\ \text{cm}} = 11100\ \text{L/(mol cm)}ε=2.5×10−5 mol/dm3×1.00 cm0.2775​=11100 L/(mol cm).

Answer: 0.750.750.75, 333 and 11100 L/(mol cm)11100\ \text{L/(mol cm)}11100 L/(mol cm).

Check. On the left the ligand runs out first: each ML3\text{ML}_{3}ML3​ needs three ligands, so the rise is a third as steep as the fall.

Log in to save this for later
← All Problems
← A drop of a purple dye is added to a large excess of sodium hydroxide solution in a cuvette…A student mixes 5.00 cm³ of 2.00 × 10⁻³ mol/dm³ iron(III) nitrate with 5.00 cm³ of 2.00 × 10⁻³… →
More onPrinciples Related to Practical Chemistry

Discussion (0)

Log in to join the discussion.

Loading…

Learn it in

  1. Colorimetry at work: rates, formulas of complexes and equilibriumColorimetry and Titration Technique: Concentration and Its Uncertainty

More on this topic

  1. Pure benzoic acid melts at 122.4 °C (395.5 K), and its enthalpy of fusion is 18.0 kJ/mol…Advanced
  2. A chemist analyses a mixture of three esters, P, Q and R, by gas chromatography…Advanced
  3. A thin-layer plate is run with a mixture M and two pure references, A and B, side by side on one…Hard
UPESEAT
VITEEE

For a first-order reaction followed by colour, ln⁡(A0/A)=kt\ln(A_0/A) = ktln(A0​/A)=kt and t1/2=ln⁡2/kt_{1/2} = \ln 2/kt1/2​=ln2/k. In the method of continuous variation the peak is at a ligand mole fraction x=n/(n+1)x = n/(n + 1)x=n/(n+1) for MLn\text{ML}_\text{n}MLn​. For an equilibrium, the absorbance gives the concentration of the coloured species, and a table of amounts gives the rest.

Benzene and toluene form a nearly ideal mixture…Advanced
  • An organic compound X is dissolved in 100 cm³ of water, and the solution holds 1.00 g of it…Hard
  • All problems on this topic →