Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
A class standardises a sodium hydroxide solution whose accepted concentration is 0.1100 mol/dm³. Maria finds 0.1128 mol/dm³. Her pipette was 25.00 cm³ () and her mean titre was 20.50 cm³ (). The other data had no uncertainty worth counting. Find her percentage error, her total percentage uncertainty, and say whether the difference can be explained by the uncertainty of the glassware. Suggest one cause, if it cannot.
Check an answer or open a hint to unlock the worked solution.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Step 1. Percentage error. .
Step 2. Percentage uncertainty. Pipette: . Titre: . Total: .
Step 3. Compare. The error, 2.55 %, is more than three times the uncertainty, 0.73 %. The glassware cannot explain it. A systematic error is present.
Step 4. A cause. Her result is too high. For example, an indicator that changed colour late would give too large a titre of acid every time, if the alkali was in the pipette.
Answer: and . The difference is too large to be explained by the uncertainty, so there is a systematic error.
Check. Repeating the titration would not help. The cause must be found and removed.
Log in to join the discussion.
Loading…
A titre has an uncertainty of (two readings of ). . For products and quotients add the percentage uncertainties; for sums and differences add the absolute ones. Concordant titres agree within 0.10 cm³. Percentage error .