Background radiation and detecting radiation · Physics… | StemPy Lab
Course 11.2·Lesson 1 of 3
Background radiation and detecting radiation
Background radiation is the ionising radiation that is always present around us, from radon gas, rocks and buildings, food and drink, and cosmic rays. A Geiger-Müller tube and a counter measure radiation as a count rate in counts per second or counts per minute. Extended: the corrected count rate is the measured count rate minus the background count rate.
about 25 min1 simulation1 practice question
Lesson 1 of 3Show all lessonsHide
Try the code and the simulations beside the lesson.
A click with nothing near it
Switch on a Geiger counter in a quiet room, with no radioactive source anywhere near. It still clicks now and then. Is the counter broken? No. It is picking up background radiation.
Background radiation
Background radiation is the ionising nuclear radiation that is always present in our surroundings. Ionising radiation is radiation that can knock electrons out of atoms. The next lesson looks at this more closely.
Most background radiation is natural. The main sources are:
radon gas in the air. It is a radioactive gas that seeps out of rocks and soil, and it can collect inside buildings;
rocks and buildings. Stone, brick and soil contain small amounts of radioactive atoms;
food and drink. They contain small amounts of radioactive atoms, such as potassium-40;
cosmic rays. These are fast particles that arrive from space. The Earth's atmosphere stops most of them, and they are stronger on a mountain top than at sea level.
A small part comes from things people have made, such as medical scans. The size of the background changes from place to place.
Detecting radiation
We cannot see, hear or feel nuclear radiation. We use a detector connected to a counter. A common detector is the Geiger-Müller tube.
A diagram of a radiation detector. On the left is a grey radioactive source, with a blue arrow labelled radiation pointing to the right towards a Geiger-Müller tube. The tube is a long box with a thin window at its left end and an orange central wire marked plus inside. A cable joins it to a counter on the right, a box with a digital display and a speaker. A note says that each particle or photon that enters makes one pulse and the counter adds up the pulses.
The tube holds a gas at low pressure. When a particle or a photon of ionising radiation enters through the thin window, it ionises the gas. A tiny pulse of current flows, and the counter adds one to its count. The counter can also click through a loudspeaker.
The count rate is the number of counts in a unit of time. We give it in counts per second (counts/s) or counts per minute (counts/min). If a counter registers 240 counts in 4 minutes, the count rate is 4240=60 counts/min.
Extended: the corrected count rate
The tube counts the background as well as the radiation from the source we study. To find the count rate due to the source alone, we use a corrected count rate.
Count for some time with the source removed. This gives the background count rate.
Count for the same kind of time with the source in place. This gives the measured count rate.
Set the source to 190 counts/min and the background to 20 counts/min. The measured rate is 210 counts/min. The corrected rate is 210−20=190 counts/min, the part that is due to the source. Now raise the background and watch the corrected rate stay the same, though the measured rate rises.
A worked example. A counter registers 135 counts in 3 minutes with a source near it. With the source removed it registers 42 counts in 3 minutes. Find the corrected count rate.
Measured rate.3135=45 counts/min.
Background rate.342=14 counts/min.
Corrected rate.45−14=31 counts/min.
Check. The answer is smaller than the measured rate, as it must be.
Emission is random, so repeated readings differ a little. We take several readings and use the average.
Practise with new numbers
Try it in Python
The program takes five one-minute counts of the background and five with a source. It averages each set and works out the corrected count rate.
Common mistakes
Forgetting the background. Even with no source the counter is counting. Always measure it.
Subtracting counts in different times. Change both to a rate first, in counts/min or counts/s, then subtract.
Thinking background radiation comes only from nuclear power. Most of it is natural.
Writing the rate without its unit. Say counts/s or counts/min.
Remember these
Background radiation is always there. Its sources include radon gas, rocks and buildings, food and drink, and cosmic rays.
A Geiger-Müller tube and a counter measure the count rate in counts/s or counts/min.