HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
Laboratory Safety and Separation: Planning, Purifying and Checking Purity
  1. 1Working safely and planning an experiment
  2. 2Separating mixtures: crystallisation, distillation and extraction
  3. 3Chromatography and tests of purity
  1. Chemistry
  2. /Laboratory Safety and Separation: Planning, Purifying and Checking Purity
  3. /Chromatography and tests of purity

Course 40.3·Lesson 3 of 3

Chromatography and tests of purity

A drop of black ink on wet paper spreads into rings of blue, red and yellow. The colours were in the ink all along, and the water carried them different distances. This lesson covers paper, thin-layer, column and gas chromatography, and how a chemist checks purity by a melting point.

about 25 min1 simulation1 practice question
Lesson 3 of 3Show all lessonsHide
Laboratory Safety and Separation: Planning, Purifying and Checking Purity
  1. 1Working safely and planning an experiment
  2. 2Separating mixtures: crystallisation, distillation and extraction
  3. 3

Try the code and the simulations beside the lesson.

How chromatography separates

Every kind of chromatography has two phases. The stationary phase stays still: the paper, a thin layer of silica on a plate, or the packing of a column. The mobile phase moves through it: a solvent or a gas. A compound that clings to the stationary phase moves slowly. One that prefers the mobile phase moves fast. So the compounds of a mixture separate.

Thin-layer and paper chromatography

  1. Draw a baseline in pencil, about 1 cm from the bottom. Ink would itself separate.
  2. Put a small spot of each sample on the line. Spot the pure reference compounds beside the mixture.
  3. Stand the plate in a little solvent in a covered tank. The solvent must be below the baseline, or the spots dissolve into it.
  4. When the solvent is near the top, mark the solvent front and let the plate dry.
  5. Find colourless spots with an ultraviolet lamp, with iodine vapour, or, for amino acids, by spraying with ninhydrin, which turns them purple.
A thin-layer chromatography plate. A pencil baseline is drawn near the bottom with three spots on it: A, a mixture M and B. The solvent front is marked near the top. Above A there is one spot; above B one spot; above M two spots, level with the spots of A and B. The distance from the baseline to a spot is labelled x and to the solvent front y, and Rf equals x divided by y.

The retardation factor is

Rf=xy\displaystyle R_f = \dfrac{x}{y}Rf​=yx​

Here xxx is the distance moved by the spot and yyy the distance moved by the solvent. Both distances are measured from the baseline, to the centre of the spot. An Rf is always between 0 and 1. It depends on the compound, the solvent and the plate, so we compare a mixture with references run on the same plate.

On silica, a polar compound clings more and has a smaller Rf. A more polar solvent moves every spot further.

Two-way chromatography. If two compounds share an Rf in one solvent, turn the plate through 90° and run it again in a second solvent.

Column chromatography

A glass column is packed with silica or alumina. The mixture goes on top, and solvent runs down through it. The least polar compound comes out first, the most polar last. Each part that comes out is collected in its own flask. This works on a larger scale than a plate.

Gas chromatography

In gas chromatography (GC) the mobile phase is a gas, such as helium or nitrogen, and the stationary phase is a liquid coated inside a long, thin column. Each compound comes out after its own retention time. The area of each peak is proportional to the amount of the compound, once each is corrected by its response factor. A-Level and IB use GC to find the composition of a mixture. High-performance liquid chromatography (HPLC) works the same way with a liquid under pressure.

Let the solvent run further. The gap between two spots grows in proportion to the distance run, so a longer plate separates better.

Practise with new numbers

Is it pure? The melting point

A pure solid melts sharply, over 1 °C or less, at a fixed temperature. An impurity does two things:

  • it lowers the melting point;
  • it broadens the range over which the solid melts.

Mixed melting point. To check that a product is compound Y, mix it with a pure sample of Y. If the melting point stays the same, the product is Y. If it falls, the product is something else.

For a small amount of impurity, the fall in the melting point is

ΔT=RT02ΔHfus ximpurity\displaystyle \Delta T = \dfrac{R T_0^2}{\Delta H_{\text{fus}}}\, x_{\text{impurity}}ΔT=ΔHfus​RT02​​ximpurity​

Here T0T_0T0​ is the melting point of the pure solid in kelvin, ΔHfus\Delta H_{\text{fus}}ΔHfus​ is its enthalpy of fusion, and xxx is the mole fraction of the impurity. Olympiad problems use this to estimate purity. A liquid is checked in the same way by its boiling point.

Try it in Python

The program turns the areas of gas chromatography peaks into a percentage composition.

Read it first. Predict which compound is the largest part. Then run it.

1. Set every response factor to 1.0. How does the answer change?

2. Add a fourth peak of area 500 with a response factor of 1.0.

Common mistakes

  • Baseline in ink, or below the solvent. Use pencil, and keep the solvent below it.
  • Measuring from the bottom of the plate. Both distances start at the baseline.
  • Using peak heights instead of areas in gas chromatography.
  • Calling a sample pure because it melts. Look for a sharp melting point at the right temperature.

Remember these

  • RfR_fRf​ = spot distance / solvent distance, from the baseline.
  • On silica: polar compounds move less. Column: the least polar comes out first.
  • GC: retention time names the compound, peak area gives the amount.
  • Impurity: lower and broader melting point.

References

  • OpenStax Chemistry 2e, Chapter 11, section 11.4 on colligative properties, for the lowering of a melting point.
  • NCERT Chemistry Part II for Class 11, Unit 8, on chromatography and the criteria of purity.

Check yourself

Try each one on your own first. If you are stuck, open a hint. Then check with Show the answer.

  1. Why is the baseline drawn in pencil and not in ink?
  1. On a silica plate, compound P has an Rf of 0.20 and compound Q has 0.65. Which is more polar?
  1. A product melts over 113 to 118 °C, while the pure compound melts at 121 °C. What does this tell you?
  1. In a gas chromatogram, why are peak areas corrected by response factors?

Enroll free in Laboratory Safety and Separation: Planning, Purifying and Checking Purity

Every lesson is open to read. Enrolling also lets you:

  • Mark lessons done and carry on where you stopped.
  • Take the tests of this lesson and its course.
  • Count the course towards the certificate for its chapter.
No payment. You can leave at any time.

Problems (3)

A thin-layer plate is run with a mixture M and two pure references, A and B, side by side on one…Hard · High School (11–12) · by StemPy Lab
A chemist analyses a mixture of three esters, P, Q and R, by gas chromatography…Advanced · High School (11–12) · by StemPy Lab
Pure benzoic acid melts at 122.4 °C (395.5 K), and its enthalpy of fusion is 18.0 kJ/mol…Advanced · High School (11–12) · by StemPy Lab
That was the last lessonBack to the course: take the test
← Laboratory Safety and Separation: Planning, Purifying and Checking Purity
← Separating mixtures: crystallisation, distillation and extractionNext →

Discussion (0)

Log in to join the discussion.

Loading…

1 Python program
4 questions to check yourself

This lesson is free to read. Enroll free to keep your place and take the tests.

Chromatography and tests of purity

Python Labs (1)

Rf values and a gas chromatogramPython Lab · by StemPy Lab

Question Sets (1)

Safety and Separation: Review Questions10 questions · by StemPy Lab

Notes (1)

Laboratory Safety and Separation: Quick RevisionNote · by StemPy Lab