Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
Soft tissue weakens ultrasound by dB for each centimetre of path and each megahertz of frequency. A scanner can make up a total loss of dB. The boundary it looks for reflects of the intensity. Find the loss in the reflection in decibel, and the deepest boundary the scanner can see at MHz and at MHz. Compare the wavelengths in tissue at the two frequencies, with m/s. Which frequency would you choose for a tendon cm under the skin, and why?
An echo from a depth returns after . Over a path the intensity falls as , and an echo travels . The Doppler shift of blood moving at is
Check an answer or open a hint to unlock the worked solution.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Step 1. The reflection. dB. That leaves dB for the path.
Step 2. At 3.5 MHz. The loss is dB for each centimetre of path. The path is , so , and cm.
Step 3. At 10 MHz. The loss is dB for each centimetre. So , and cm.
Step 4. The wavelengths. mm and mm.
Answer: dB, cm and cm. The wavelengths are mm and mm.
The choice. For a tendon at cm, use MHz. It reaches far deeper than needed and shows detail almost three times finer. For the liver of an adult, at to cm, only the lower frequency reaches.
Log in to join the discussion.