HelpContactFor teachers and institutes
>_StemPy Lab
Mock TestsClasses

>_StemPy Lab

Learn. Solve. Code the solutions. Test yourself.

Live examsFree mock exams, timed and rankedEveryone starts together, and your score and rank come the moment it ends.See the exams →
Live examsInternational live exams are comingTell us which exam you want first. Timed practice papers are open now.See what is coming →

Learn

  • Physics
  • Chemistry
  • Mathematics
  • Biology
  • Python Programming
  • Statistics & Data Science
  • Computer Science
  • Space Science and Astronomy
  • Classes
  • Groups

Practice

  • Problems
  • Quizzes
  • Mock Tests
  • Prepare for an Exam
  • Question Sets
  • Exams
  • Certificates
  • Python Labs
  • AI Practice Generator
  • Student-Created Tests

Community

  • Discussions
  • Resources
  • Notes
  • Glossary
  • Blog

Account

  • Log in
© 2026 senLearn. All rights reserved.HelpFor SchoolsAboutContactPrivacy PolicyTerms of UseRefund Policy
  1. Problems
  2. /Soft tissue weakens ultrasound by 0.50 dB for each centimetre of path and each megahertz of…
AdvancedPhysicsHigh School (11–12)Medical PhysicsNumericalpythonA-Level

Soft tissue weakens ultrasound by 0.50 dB for each centimetre of path and each megahertz of…

StemPy LabContributed by StemPy Lab

Try it on paper first. A hint, the key idea and the worked solution are here when you need them.

Soft tissue weakens ultrasound by 0.500.500.50 dB for each centimetre of path and each megahertz of frequency. A scanner can make up a total loss of 100100100 dB. The boundary it looks for reflects 1.0 %1.0\ \%1.0 % of the intensity. Find the loss in the reflection in decibel, and the deepest boundary the scanner can see at 3.53.53.5 MHz and at 101010 MHz. Compare the wavelengths in tissue at the two frequencies, with c=1540c = 1540c=1540 m/s. Which frequency would you choose for a tendon 1.51.51.5 cm under the skin, and why?

Check your answer

Work it out on paper, then type your number. The answer itself stays hidden.

dB
cm
cm
mm
Need a reminder? The key ideaShowHide

An echo from a depth ddd returns after t=2d/ct = 2d/ct=2d/c. Over a path xxx the intensity falls as I=I0e−kxI = I_0e^{-kx}I=I0​e−kx, and an echo travels x=2dx = 2dx=2d. The Doppler shift of blood moving at vvv is

Δf=2fvcos⁡θc\displaystyle \Delta f = \frac{2fv\cos\theta}{c}Δf=c2fvcosθ​

The worked solution

Check an answer or open a hint to unlock the worked solution.

Have you tried it?

Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.

Step 1. The reflection. 10log⁡1010.010=2010\log_{10}\dfrac{1}{0.010} = 2010log10​0.0101​=20 dB. That leaves 808080 dB for the path.

Step 2. At 3.5 MHz. The loss is 0.50×3.5=1.750.50 \times 3.5 = 1.750.50×3.5=1.75 dB for each centimetre of path. The path is 2d2d2d, so 1.75×2d=801.75 \times 2d = 801.75×2d=80, and d=22.9d = 22.9d=22.9 cm.

Step 3. At 10 MHz. The loss is 5.05.05.0 dB for each centimetre. So 5.0×2d=805.0 \times 2d = 805.0×2d=80, and d=8.0d = 8.0d=8.0 cm.

Step 4. The wavelengths. 1540 m/s3.5×106 Hz=0.440\dfrac{1540\ \text{m/s}}{3.5 \times 10^6\ \text{Hz}} = 0.4403.5×106 Hz1540 m/s​=0.440 mm and 1540 m/s10×106 Hz=0.154\dfrac{1540\ \text{m/s}}{10 \times 10^6\ \text{Hz}} = 0.15410×106 Hz1540 m/s​=0.154 mm.

Answer: 202020 dB, 22.922.922.9 cm and 8.08.08.0 cm. The wavelengths are 0.4400.4400.440 mm and 0.1540.1540.154 mm.

The choice. For a tendon at 1.51.51.5 cm, use 101010 MHz. It reaches far deeper than needed and shows detail almost three times finer. For the liver of an adult, at 101010 to 151515 cm, only the lower frequency reaches.

Log in to save this for later
← All Problems
← Before a cataract operation, the length of the eye is measured with an A-scan…A 5.0 MHz Doppler probe is held so that its beam makes an angle of 60° with an artery in the neck… →
More onMedical Physics

Discussion (0)

Log in to join the discussion.

Loading…

Learn it in

  1. Ultrasound scans, attenuation and Doppler flowUltrasound, Hearing and Sight

More on this topic

  1. A tumour of mass 0.12 kg is to receive 60 Gy in 30 equal fractions…Advanced
  2. After a large dose of iodine-131, a patient gives a dose rate of 25 microsievert per hour at 1.0 m…Hard
  3. At the start of a scan, a patient holds 300 MBq of fluorine-18, whose half-life is 109.8 min…Advanced
A cyclotron makes fluorine-18, with a half-life of 109.8 min, for a hospital 2.0 h away…Hard
  • A PET ring has a diameter of 80 cm. For one event, the photon that reaches detector A arrives 300…Hard
  • All problems on this topic →