A meter bridge is a Wheatstone bridge made with a uniform wire 100cm long and a sliding contact. At balance, RX=100−ll
about 30 min1 simulation2 practice questions1 Python program5 questions to check yourself
This lesson is free to read. Enroll free to keep your place in the course.
Lesson 2 of 3Show all lessonsHide
Try the code and the simulations beside the lesson.
A Wheatstone bridge you can slide
In Electric Circuits you met the Wheatstone bridge: four resistors in a diamond, and a galvanometer that reads zero when the ratios of the arms are equal. The meter bridge is the same bridge, built with a wire so that we can change one ratio smoothly.
A uniform wire, 100cm long, lies along a scale. A strip of copper above it has two gaps. The unknown resistance X goes in one gap, and a resistance box R in the other. A galvanometer joins the middle of the strip to a sliding contact, the jockey J, which touches the wire. A cell and a key send current through the whole arrangement.
A meter bridge. A straight wire, 100 centimetres long, lies along a scale marked from 0 to 100 centimetres. A copper strip runs above it with two gaps: an unknown resistance X in the left gap and a resistance box R in the right gap. The two ends of the strip are joined down to the two ends of the wire. A galvanometer G is joined to the middle of the strip and, by a lead drawn in purple, to a sliding contact called the jockey, which touches the wire near the 36 centimetre mark. A cell and a key are joined across the two ends of the wire below it. A blue arrow marks the length l from the left end to the jockey, and an orange arrow marks the rest of the wire, 100 minus l.
The wire is uniform. Its resistance, ρL/A, is proportional to its length, because ρ and A are the same everywhere. The jockey cuts the wire into a piece of length l on the left and a piece of length 100−l on the right. Their resistances are in the ratio l:(100−l).
The balance rule
Slide the jockey until the galvanometer shows no deflection. The bridge is balanced. The four arms are X, R and the two pieces of wire. The balance condition for any Wheatstone bridge then gives
RX=100−llsoX=R100−ll
The length l is measured from the end of the wire that is joined to X. Mixing up the two ends is the commonest slip.
A worked example. A 20Ω box is in the right gap. The bridge balances with the jockey at 36.0cm.
The lengths.l=36.0cm and 100−l=64.0cm.
The resistance.X=20Ω×64.036.0=11.25Ω.
Notice that the answer does not depend on the emf of the cell, or on the resistance of the galvanometer. At balance no current flows through the galvanometer, so neither of them matters.
Set X=12Ω and R=20Ω. Find the balance point. Then make X larger and watch the balance point move. Which way does it go, and why?
Why the balance point should be near the middle
The only measurement is l, read from a scale to about 0.1cm. Suppose l is uncertain by δl. Then X=Rl/(100−l) is uncertain too. The fractional error is
XδX=δl(l1+100−l1)=l(100−l)100δl
The bottom line, l(100−l), is greatest at l=50cm. So the error is smallest there. With δl=0.1cm:
At 50cm, the error in X is 0.40%.
At 20cm, it is 0.63%.
At 10cm, it is 1.1%.
So choose R close to X in size. Then the balance point falls between 40cm and 60cm, where the reading is best.
Reducing the errors
End corrections. The copper strips and the joints add small resistances at the ends of the wire. Then the lengths that count are a little longer than the lengths we read. The balance rule is slightly wrong.
Interchange. Swap X and R and balance again at l2. Now X=Rl2100−l2. The two values of X err in opposite directions, so their average is closer to the truth.
Heating. Press the key only while you take a reading. A warm wire changes its resistance.
The jockey. Tap it on the wire. Do not drag it, or the wire wears unevenly and stops being uniform.
Finding the resistivity of a wire
Suppose X is a wire of length L and diameter d. Then X=ρL/A and A=πd2/4, so
ρ=4Lπd2X
Measure X with the meter bridge. Measure L with a scale and d with a screw gauge. The diameter has the largest error, since it enters as a square.
Practise with new numbers
Try it in Python
The program finds X and the error in X for several balance points, with a 20Ω box.
Common mistakes
Turning the ratio upside down. The length l on the side of X goes on top: RX=100−ll.
Measuring l from the wrong end. It must be from the end where X is joined.
Saying the answer depends on the cell. At balance no current flows in the galvanometer, so the emf does not matter.
Forgetting that the error depends on both lengths. Only l is read, but both l and 100−l change together.
Remember these
Balance:X=R100−ll, with l measured from the side of X.
Independent of: the emf of the cell and the resistance of the galvanometer.
Best accuracy: a balance point near 50cm.
Fractional error:l(100−l)100δl.
Interchange X and R:X=Rl2100−l2. Average the two values.
Resistivity:ρ=4Lπd2X.
Check yourself
Try each one on your own first. If you are stuck, open a hint. Then check with Show the answer.
A resistance box of 30Ω is in the right gap of a meter bridge. The balance point is 45cm from the left end. What is X?
X and R are interchanged, and the new balance point is at l2. Where was the first balance point, in terms of l2?
Why is it better to balance near the middle of the wire?
Does the balance point change if the cell is replaced by one with twice the emf?