Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
The viscosity of water is at and at . Assume . (a) Find the activation energy of viscous flow. (b) Predict the viscosity at and at . (c) The measured values are and . By what percentage is each prediction off?
Poiseuille: . Stokes: a steady speed , valid when is below about . Ostwald viscometer: . For a liquid, , which falls as rises.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Given. with , and with .
Step 1. The activation energy. .
Step 2. At . , and .
So .
Step 3. At . , and the same formula gives .
Step 4. The errors. At : . At : .
Check. Predictions that are within about over a range of show that the Arrhenius form is a good model for the viscosity of water.
Answer: , at and at .