Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
A smoke alarm contains americium-241, which gives out alpha radiation and has a half-life of years. (a) What fraction of the americium is left after years? (b) What fraction is left after years? (c) Give two reasons why an alpha source is used.
The type of radiation and the half-life decide which isotope is used for a job. To cut the dose, reduce the time, increase the distance and use shielding.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Step 1. After 432 years. This is half-life, so is left.
Step 2. After 864 years. This is half-lives, so is left.
Step 3. Why alpha. Alpha particles ionise the air strongly, which makes the small current that the alarm watches. Smoke absorbs the alpha particles and the current falls. Also, alpha particles are stopped by the case of the alarm, so they do not leave it.
Answer: ; ; strong ionisation of air, and no escape through the case.
Check. The long half-life means that the alarm works for its whole life.