Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
A manual station of the National Air Quality Monitoring Programme took all its planned samples of in one year. of them were above the 24-hour standard of , and the annual mean was . (a) How many samples did it take, and why that number? (b) What percentage of the samples broke the 24-hour standard? (c) What is the exceedance factor against the annual standard of , and its grade? (d) Which objective of NAMP do these results serve?
Check an answer or open a hint to unlock the worked solution.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Step 1. Samples. Twice a week for 52 weeks gives samples.
Step 2. Share above. .
Step 3. Factor. , which is above : critical.
Step 4. Objective. The results show whether the standards are broken, and they mark the city as a non-attainment city. That is the second and third objectives of NAMP.
Answer: 104; ; , critical; finding violations and non-attainment cities.
Log in to join the discussion.
Loading…
Under NAMP each pollutant is sampled for 24 hours, twice a week: 104 samples a year. Its objectives: status and trends, violations of the standards, non-attainment cities, knowledge for preventive and corrective measures, and the natural cleansing of the air.