Try it on paper first. A hint, the key idea and the worked solution are here when you need them.
A germanium bar is zone refined. For one impurity the distribution coefficient is : the solid that freezes takes one tenth of the impurity in the melt. Use the one-pass formula in the reminder, with the bar much longer than the zone. Find the impurity left at the very start of the bar, as a share of the old value, and the share left two zone lengths in. Then find how many zone lengths stay below half of the old value.
Electrolytic refining: the impure metal dissolves at the anode, pure metal plates on the cathode, and the less reactive metals fall into the anode mud. Zone refining after one pass: . Mond: . Van Arkel: . One mole of gas fills at 273 K and 1 atm.
Check an answer or open a hint to unlock the worked solution.
Have you tried it?
Work it out on paper first. It is fine to get stuck or make a mistake: that is how we learn. When you are ready, go through the solution one step at a time, and check each step against your own.
Step 1. Start. .
Step 2. Two zone lengths. .
Step 3. Half. , so and .
Answer: , and zone lengths.
Check. After one pass only the first six zone lengths are better than half clean. That is why the pass is repeated many times for semiconductor purity.
Source. The one-pass formula is the standard result of W. G. Pfann for zone melting.
Log in to join the discussion.