A brief note on Air Quality Standards, Water and Soil Testing . Read it before a test. Try each question at the end before you open its answer.
Air quality standards Standard: a legal limit on a pollutant in the ambient air, over an averaging time. Objectives: protect health, plants and property; set priorities; one yardstick; guide monitoring. CPCB (Water Act 1974, Air Act 1981): advises, plans, coordinates the State Boards, sets standards, publishes data. SPCB: consent to establish and to operate, inspection, state limits, action against offenders. NAAQM is now NAMP : status and trends, violations, non-attainment cities, measures, natural cleansing. NAAQS 2009: twelve pollutants. 24-hour PM 2.5 \text{PM}_{2.5} PM 2.5 : India 60, WHO 15. Annual PM 2.5 \text{PM}_{2.5} PM 2.5 : India 40, WHO 5 ( μ g/m 3 \mu\text{g/m}^3 μ g/m 3 ). Exceedance factor: annual mean ÷ \div ÷ standard. Above 1.5 1.5 1.5 critical. Water EC: dissolved salts. Turbidity: suspended particles (NTU). pH: 6.5 6.5 6.5 to 8.5 8.5 8.5 . DO: less in warm water; low DO means organic pollution. Faecal coliforms: sewage. Hardness: 2.50 [ Ca ] + 4.12 [ Mg ] 2.50[\text{Ca}] + 4.12[\text{Mg}] 2.50 [ Ca ] + 4.12 [ Mg ] as CaCO 3 \text{CaCO}_3 CaCO 3 . Nitrates: eutrophication, blue babies. Sulphates: taste. BOD: ( D 1 − D 2 ) / P (D_1 - D_2)/P ( D 1 − D 2 ) / P , 5 days at 20 ∘ C 20\ ^\circ\text{C} 20 ∘ C . COD: dichromate, ( A − B ) N × 8000 / V (A - B)N \times 8000/V ( A − B ) N × 8000/ V . COD is usually larger than BOD. Soil Good indicator: responds to management, cheap, repeatable, linked to soil functions, easy to read. Biological: respiration, earthworms. Physical: aggregates, infiltration. Chemical: pH, conductivity, nutrients. Respiration: 22 ( B − V ) N 22(B - V)N 22 ( B − V ) N mg of carbon dioxide. pH: 1 to 2.5 suspension; lime for acid, gypsum for alkaline. Aggregates: slake test. Infiltration: ring test, depth ÷ \div ÷ time. Usual slips Comparing a daily value with an annual standard. Treating WHO guidelines as law. Forgetting the dilution in a BOD bottle. Using the first, fast ring reading as the rate. Check yourself Which board would close a polluting factory in Kerala? Stuck? Show a hint Show the answerWhy does a river's dissolved oxygen fall below a sewage outlet? Stuck? Show a hint Show the answerWhich soil indicator does a slake test measure? Stuck? Show a hint Show the answerSources Central Pollution Control Board, National Ambient Air Quality Standards (2009) and the National Air Quality Monitoring Programme. Bureau of Indian Standards, IS 10500:2012 Drinking Water Specification. United States Department of Agriculture, Soil Quality Test Kit Guide.